DocumentCode :
2107655
Title :
Stator core faults detection on induction motor drives using signal injection
Author :
de la Barrera, P.M. ; Bossio, G.R.
Author_Institution :
CONICET, Rio Cuarto, Argentina
fYear :
2011
fDate :
5-8 Sept. 2011
Firstpage :
98
Lastpage :
104
Abstract :
A novel method to detect stator core fault (SCF) for induction motor (IM) drives is proposed in this paper. This approach is based on the effect of the SCF over the zero sequence voltage of the IM when a preset exploratory signal is injected in the machine. The validity of the proposed method is demonstrated by experimental results obtained with a modified standard IM. The modification allows to electrically emulate a SCF. This methodology used to perform SCF is experimentally validated by using the well known loop test. Obtained results show the applicability and the good performance of the SCF detection method.
Keywords :
fault diagnosis; induction motor drives; induction motor drives; loop test; modified standard induction motor; preset exploratory signal; signal injection; stator core faults detection; zero sequence voltage; Insulation; Inverters; Lamination; Stator cores; Stator windings; Voltage measurement; Induction motor drives; signal injection; stator core faults;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Diagnostics for Electric Machines, Power Electronics & Drives (SDEMPED), 2011 IEEE International Symposium on
Conference_Location :
Bologna
Print_ISBN :
978-1-4244-9301-2
Electronic_ISBN :
978-1-4244-9302-9
Type :
conf
DOI :
10.1109/DEMPED.2011.6063608
Filename :
6063608
Link To Document :
بازگشت