Abstract :
The inverter pulse resistant magnet wire, Thermaleze Q´, was developed and introduced to the market in September 1995. Since then, laboratory accelerated motor tests as well as field tests have been performed in many different inverter-fed motor applications. It has been proved to be a greatly improved product for inverter-fed motor applications. However, an accelerated lab test on twisted pairs at elevated temperatures indicated that the current version of this wire has its limitations in high-temperature applications. Therefore, an improved version is being developed. The dielectric performance of this improved wire in comparison to current Quantumshield is presented and discussed in this paper
Keywords :
DC-AC power convertors; PWM invertors; cable testing; electric breakdown; electric motors; insulated wires; insulation testing; life testing; wires (electric); Quantumshield; Thermaleze Q´ magnet wire; accelerated laboratory tests; dielectric performance; high-temperature applications; inverter-fed motors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation Conference, 1997, and Electrical Manufacturing & Coil Winding Conference. Proceedings
Conference_Location :
Rosemont, IL
ISSN :
0362-2479
Print_ISBN :
0-7803-3959-2
Type :
conf
DOI :
10.1109/EEIC.1997.651157
Filename :
651157
Link To Document :
بازگشت