Abstract :
A new method to detect fault conditions in inverter fed AC machines caused by asymmetries in the airgap is presented in this contribution. In the first part the influence of these asymmetries on the transient electrical behavior of the machine is investigated by simulation results obtained from a magnetic equivalent circuit model. Starting from these results the proposed method is derived. It is based on the reaction of the machine current to voltage pulses caused by the switching of the inverter. The continuous switching of the inverter is necessary for the current control loop during normal operation of the drive. Using a special observer structure any changes in the reaction of the machine caused by airgap asymmetries can be detected and isolated. The only inputs necessary for the realization of the method are the DC link values of the voltage and the current. The observer estimates the transient parameters of the three phases and by comparing the three phase values an error signal can be calculated. The method is insensitive to changes of the machine parameters due to temperature or saturation as long as these changes occur symmetrically in all three phases. The method is applicable in both steady state and transient operation. The practical operation of the method is verified by measurement results at different points of operation and with different fault positions/magnitudes.
Keywords :
air gaps; electric current control; equivalent circuits; fault diagnosis; induction motor drives; invertors; machine control; magnetic circuits; observers; rotors; switching; 12 kW; DC link current; DC link voltage; airgap asymmetries; continuous switching; current control loop; error signal; fault conditions detection; fault magnitude; fault position; inverter fed AC machines; inverter switching; machine current; magnetic equivalent circuit model; observer based detection; observer structure; rotor eccentricity; steady state operation; transient electrical behavior; transient operation; transient parameters estimation; voltage pulses; AC machines; Circuit faults; Circuit simulation; Current control; Electrical fault detection; Equivalent circuits; Parameter estimation; Pulse inverters; Saturation magnetization; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003. 4th IEEE International Symposium on
Print_ISBN :
0-7803-7838-5
Type :
conf
DOI :
10.1109/DEMPED.2003.1234595
Filename :
1234595
Link To Document :
بازگشت