DocumentCode :
2111695
Title :
Component assessment for IEC 61508 - a worked example
Author :
Smith, P.R.
Author_Institution :
Moore Ind.-Europe
fYear :
2004
fDate :
16-16 Sept. 2004
Firstpage :
97
Abstract :
A 3-wire RTD is used to illustrate the methodology involved with assessing a component for use in a safety instrumented loop
Keywords :
failure analysis; safety systems; sensors; 3-wire RTD; IEC 61508; component assessment; failure fraction; random failure; safety instrumented loop;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Is Your Product Safe? - IEE Seminar on (Ref. No. 2004/10724)
Conference_Location :
London
ISSN :
0537-9989
Print_ISBN :
0-86341-456-7
Type :
conf
DOI :
10.1049/ic:20040544
Filename :
1514211
Link To Document :
بازگشت