• DocumentCode
    2111952
  • Title

    Online surge testing applied to an induction machine with emulated insulation breakdown

  • Author

    Grubic, Stefan ; Habetler, Thomas G. ; Restrepo, Jose

  • Author_Institution
    Sch. of Electr. & Comput. Eng., Georgia Inst. of Technol., Atlanta, GA, USA
  • fYear
    2011
  • fDate
    17-22 Sept. 2011
  • Firstpage
    449
  • Lastpage
    456
  • Abstract
    A breakdown of the electrical insulation system can cause catastrophic failure of the electrical machine and bring large process downtime losses. Preventive maintenance and online monitoring are some of the methods to improve reliability and reduce unscheduled downtime. One of the main reasons for the failure is the breakdown of the stator insulation. The offline surge test is the most commonly used offline test to assess the condition of the turn insulation. There is no online monitoring method that is applicable to low voltage machines and has the same capabilities as the surge test. This paper shows how to conduct a surge test online. The required hardware and the test procedures are described. A new test setup that emulates the arcing due to a weak turn insulation is used to validate the technique proposed.
  • Keywords
    arcs (electric); asynchronous machines; electric breakdown; insulation testing; machine insulation; preventive maintenance; surges; catastrophic failure; downtime losses; emulated insulation breakdown; induction machine; offline surge test; online surge testing; preventive maintenance; stator insulation; Ear; Electric breakdown; Inductance; Insulation; Rotors; Stators; Surges;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition (ECCE), 2011 IEEE
  • Conference_Location
    Phoenix, AZ
  • Print_ISBN
    978-1-4577-0542-7
  • Type

    conf

  • DOI
    10.1109/ECCE.2011.6063804
  • Filename
    6063804