DocumentCode
2111952
Title
Online surge testing applied to an induction machine with emulated insulation breakdown
Author
Grubic, Stefan ; Habetler, Thomas G. ; Restrepo, Jose
Author_Institution
Sch. of Electr. & Comput. Eng., Georgia Inst. of Technol., Atlanta, GA, USA
fYear
2011
fDate
17-22 Sept. 2011
Firstpage
449
Lastpage
456
Abstract
A breakdown of the electrical insulation system can cause catastrophic failure of the electrical machine and bring large process downtime losses. Preventive maintenance and online monitoring are some of the methods to improve reliability and reduce unscheduled downtime. One of the main reasons for the failure is the breakdown of the stator insulation. The offline surge test is the most commonly used offline test to assess the condition of the turn insulation. There is no online monitoring method that is applicable to low voltage machines and has the same capabilities as the surge test. This paper shows how to conduct a surge test online. The required hardware and the test procedures are described. A new test setup that emulates the arcing due to a weak turn insulation is used to validate the technique proposed.
Keywords
arcs (electric); asynchronous machines; electric breakdown; insulation testing; machine insulation; preventive maintenance; surges; catastrophic failure; downtime losses; emulated insulation breakdown; induction machine; offline surge test; online surge testing; preventive maintenance; stator insulation; Ear; Electric breakdown; Inductance; Insulation; Rotors; Stators; Surges;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2011 IEEE
Conference_Location
Phoenix, AZ
Print_ISBN
978-1-4577-0542-7
Type
conf
DOI
10.1109/ECCE.2011.6063804
Filename
6063804
Link To Document