Title :
Analysis on the location of Stratified interface in Density Lock
Author :
Yu Pei ; Yan Cang-qi
Author_Institution :
Coll. of Nucl. Sci. & Technol., Harbin Eng. Univ., Harbin, China
Abstract :
A theoretical model is built to calculate the location of fluid stratified interface in density lock, and is verified experimentally .Then the effects of grid shape and grid size on the interface location are discussed, respectively. Interface location is independent of grid shape, but the larger grid size responds to the lower interface location.
Keywords :
channel flow; fission reactor cooling; fission reactor safety; heat transfer; mass transfer; stratified flow; density lock; fluid stratified interface location calculation; grid shape; grid size; hydraulic balance; passive safety technology; reactor cooling system; stratified interface location analysis; theoretical model; Circuit testing; Cooling; Educational institutions; Inductors; Nuclear and plasma sciences; Safety; Shape; Steel; Turbines; Water resources;
Conference_Titel :
Power and Energy Engineering Conference (APPEEC), 2010 Asia-Pacific
Conference_Location :
Chengdu
Print_ISBN :
978-1-4244-4812-8
Electronic_ISBN :
978-1-4244-4813-5
DOI :
10.1109/APPEEC.2010.5449209