• DocumentCode
    2112819
  • Title

    UPS flux compensation techniques for transformer inrush reduction

  • Author

    Yeh, Ming-Yang ; Chen, Yu-Hsing ; Cheng, Po-Tai ; Liao, Steven ; Tsai, Charles

  • Author_Institution
    Center for Adv. Power Technol., Nat. Tsing Hua Univ., Hsinchu, Taiwan
  • fYear
    2011
  • fDate
    May 30 2011-June 3 2011
  • Firstpage
    1060
  • Lastpage
    1065
  • Abstract
    This paper presents two flux compensation designs for the uninterruptible power supply system. The objective of the flux compensation is to reduce the potential inrush current of the uninterruptible power supply-fed load transformer in the event of grid disturbances and load transformer engagement. The proposed methods utilize the existing voltage and current sensors, and voltage and current control loops of the uninterruptible power supply system for easy implementation. The application scenario is explained, and details of the flux compensation techniques are presented Laboratory test results are provided for validation.
  • Keywords
    electric current control; power supply quality; transformers; uninterruptible power supplies; voltage control; UPS flux compensation technique; current closed-loop control; current sensor; grid disturbance; transformer inrush reduction; uninterruptible power supply system; voltage control; voltage sensor; Circuit faults; Couplings; Inverters; Surge protection; Surges; Uninterruptible power systems; Voltage control; flux compensation; inrush current; power quality; uninterruptible power supplies; voltage sags;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and ECCE Asia (ICPE & ECCE), 2011 IEEE 8th International Conference on
  • Conference_Location
    Jeju
  • ISSN
    2150-6078
  • Print_ISBN
    978-1-61284-958-4
  • Electronic_ISBN
    2150-6078
  • Type

    conf

  • DOI
    10.1109/ICPE.2011.5944706
  • Filename