DocumentCode
2113113
Title
How to be sure that switched Ethernet networks satisfy the real-time requirements of an industrial application?
Author
Georges, J.-P. ; Rondeau, Eric ; Divoux, T.
Author_Institution
Faculte des Sci., CRAN - CNRS, Vandoeuvre les Nancy, France
Volume
1
fYear
2002
fDate
2002
Firstpage
158
Abstract
The Ethernet network is more and more used to interconnect industrial devices. The objective of this paper is to study the performances of such a network to support real-time communications. For this, we first propose a general representation to model a switched Ethernet network by using a sequence of elementary components such as buffers, multiplexers, etc. Secondly, we aggregate the individual temporal properties of each component given in the Cruz survey to obtain a global formula enabling calculation of the maximum end-to-end delay for any industrial communication scenarios.
Keywords
data communication; local area networks; real-time systems; buffers; elementary components; end-to-end delay; global formula; industrial application; industrial communication scenarios; industrial devices interconnection; multiplexers; real-time communications; real-time requirements; switched Ethernet networks;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on
Print_ISBN
0-7803-7369-3
Type
conf
DOI
10.1109/ISIE.2002.1026058
Filename
1026058