DocumentCode
2115077
Title
Fault-tolerant modulation strategy with direct duty-ratio PWM for matrix converter-fed motor drives
Author
Li, Yulong ; Choi, Nam-Sup ; Han, Byung-Moon ; Nho, Eui-Cheol
Author_Institution
Hyundai Heavy Ind. Co., Ltd., Gunsan, South Korea
fYear
2011
fDate
May 30 2011-June 3 2011
Firstpage
2891
Lastpage
2898
Abstract
Direct duty-ratio PWM schemes for continuous fault tolerant operation of matrix converter-fed motor drives are presented. The proposed method features simple modular modulation structure based on per output phase concept, which requires no additional modification on the normal modulation schemes for fault-tolerant applications. Realizations of fault-tolerant strategy applied to different system configurations are also treated to enhance the system flexibility. The proposed method can be effectively applied to treat the motor open phase fault and converter switching device failure. Simulation results will be provided to verify the feasibility and availability.
Keywords
PWM power convertors; fault tolerance; matrix convertors; motor drives; switching convertors; converter switching device failure; direct duty-ratio PWM scheme; fault-tolerant modulation strategy; matrix converter-fed motor drives; modular modulation structure; motor open phase fault; Circuit faults; Fault tolerance; Fault tolerant systems; Manganese; Matrix converters; Modulation; Switches; Fault-tolerant; PWM; matrix converter; motor drive;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and ECCE Asia (ICPE & ECCE), 2011 IEEE 8th International Conference on
Conference_Location
Jeju
ISSN
2150-6078
Print_ISBN
978-1-61284-958-4
Electronic_ISBN
2150-6078
Type
conf
DOI
10.1109/ICPE.2011.5944788
Filename
5944788
Link To Document