DocumentCode
2115665
Title
Study on Coupling Characteristics of Inductive Power Transfer System
Author
Deng Yafeng ; Wang Changsong ; Wang Hui ; Wang Shuo
Author_Institution
Sch. of Mech. Eng., Univ. of Sci. & Technol. Beijing, Beijing, China
fYear
2010
fDate
28-31 March 2010
Firstpage
1
Lastpage
4
Abstract
The core and base of inductive power transfer system were coupling performance between primary and secondary coils.The practical issues of lateral misalignment and angular misalignment between primary and secondary coils were few. This paper presented a detailed theoretical analysis of misalignment effects in inductive power transfer system,including lateral and angular misalignments. Theoretical calculation formula was simplified by using series expression of elliptic integral.An universality calculation formula of mutual inductance was obtained. And the conclusions were verified through the experimental contrast.
Keywords
coils; inductive power transmission; angular misalignment; coupling performance; elliptic integral; inductive power transfer system; lateral misalignment; mutual inductance; series expression; Coils; Inductance; Instruments; Mechanical engineering; Mutual coupling; Performance analysis; Power supplies; Power transmission; Telecommunications;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Engineering Conference (APPEEC), 2010 Asia-Pacific
Conference_Location
Chengdu
Print_ISBN
978-1-4244-4812-8
Electronic_ISBN
978-1-4244-4813-5
Type
conf
DOI
10.1109/APPEEC.2010.5449325
Filename
5449325
Link To Document