• DocumentCode
    2119376
  • Title

    The detection of cable tension based on ERA

  • Author

    Hongqiong Zhou ; Zhou, Hongqiong ; Zhan, Qing ; Ye, Qingwei

  • Author_Institution
    Faculty of Information Science and Engineering, Ningbo University, China
  • fYear
    2010
  • fDate
    4-6 Dec. 2010
  • Firstpage
    2448
  • Lastpage
    2451
  • Abstract
    The frequency domain analysis is one of the most widely used methods for tension cable test. A new method is put forward in this paper to extract the modal parameters from the vibration signal of tension cables. The ERA algorithm is used as the core of the new method. And the comparative analysis between ERA method and traditional method is also demonstrated. To detect cable tension by using ERA, more accurate and stable fundamental frequency of corresponding vibration signal of tension cable will be obtained. The new method is applied to some cable-stayed bridges of Ningbo City. The experimental and calculation results indicate that the new method can extract the domain frequency of tension cable more accurately, stably and effectively.
  • Keywords
    Amorphous silicon; Logic gates; Plastics; Stress; Substrates; Thin film transistors; Eigensystem Realization Algorithm; Frequency Domain Analysis; Modal Parameter; Random Decrement Technique;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Information Science and Engineering (ICISE), 2010 2nd International Conference on
  • Conference_Location
    Hangzhou, China
  • Print_ISBN
    978-1-4244-7616-9
  • Type

    conf

  • DOI
    10.1109/ICISE.2010.5690091
  • Filename
    5690091