DocumentCode
2119701
Title
Development of a water flow diverter with dividing body driven by stepping motor
Author
Shengjie Li ; Lijun Sun ; Tao Zhang ; Lei Qi ; Yi Liu
Author_Institution
Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China
fYear
2012
fDate
21-23 April 2012
Firstpage
280
Lastpage
283
Abstract
A water flow diverter is an essential and error determining component of a liquid flow facility based on a static gravimetric system with flying start and finish. A new diverter was developed in order to reduce the uncertainty, noise and vibration by using a stepping motor to drive the dividing body. The reasons of the diverter timing error and test methods were studied. It is shown by the test results that the uncertainty of the diverter is better than 0.007%.
Keywords
divertors; stepping motors; diverter test methods; diverter timing error methods; dividing body; error determining component; essential determining component; liquid flow facility; static gravimetric system; stepping motor; vibration; water flow diverter; Calibration; Fluid flow; Fluid flow measurement; Measurement uncertainty; NIST; Publishing; Weight measurement; flow measurement; liquid flow facility; stepping motor; timing error; water flow diverter;
fLanguage
English
Publisher
ieee
Conference_Titel
Consumer Electronics, Communications and Networks (CECNet), 2012 2nd International Conference on
Conference_Location
Yichang
Print_ISBN
978-1-4577-1414-6
Type
conf
DOI
10.1109/CECNet.2012.6201732
Filename
6201732
Link To Document