DocumentCode
2119915
Title
Thermal modeling accuracy of hourly averaged data for large free Field Cadmium telluride PV arrays
Author
Hayes, William ; Panchula, Alex ; Nelson, Lauren
Author_Institution
First Solar Inc, San Francisco, CA, 94105, USA
fYear
2012
fDate
3-8 June 2012
Firstpage
1
Lastpage
4
Abstract
Evaluating the accuracy of the PVsyst thermal model for large scale free-field thin film photovoltaic installations (> 1MW) using measured module temperatures from 4 PV systems reveals that the default thermal parameters within PVsyst over-estimate the cell temperature of the First Solar Cadmium Telluride thin film modules by 3–5 degrees Celsius. This results in a slight conservatism in the energy predicted for First Solar´s utility scale projects. A more accurate representation of module temperature can be achieved by using a thermal loss coefficient of Uc = 30.7 rather than the PVsyst default of Uc = 29.0 which results in an increase in predicted DC energy of 0.22% to 0.32% on an annual basis.
Keywords
Atmospheric modeling; Q measurement; Temperature measurement; Thermal analysis; Wind speed; cadmium; modeling; photovoltaic systems; temperature;