DocumentCode
2120602
Title
Millimeter Wave Antenna Phase Pattern Measurement using the Differential Phase Method with Only One Power Meter
Author
Mallat, Juha ; Lehto, Arto ; Tuovinen, Jussi
Author_Institution
Helsinki University of Technology, Radio Laboratory, Otakaari 5 A, FIN-02150 Espoo, Finland, FAX: 358-0-451-2152
Volume
1
fYear
1994
fDate
5-9 Sept. 1994
Firstpage
980
Lastpage
985
Abstract
The differential phase measurement method has been improved to need the use of only one power meter instead of three power meters. This enables accurate antenna phase pattern measurements with a simplified set-up, accompanied by the reduction in cost. All advantages of the differential phase measurement method are still also present, e.g. there is no need to phase lock oscillators or to use rotary joints. Measurement results for an antenna at 110 GHz are presented. A comparison t earlier data shows good agreement.
Keywords
Antenna measurements; Costs; Millimeter wave measurements; Millimeter wave technology; Oscillators; Phase measurement; Power measurement; Receiving antennas; Rotation measurement; Transmitting antennas;