• DocumentCode
    2120957
  • Title

    Implementation of a new spherical near-field range at NPL

  • Author

    Miller, Philip ; Tian, Zhengrong

  • Author_Institution
    Nat. Phys. Lab., Teddington, UK
  • fYear
    2004
  • fDate
    25-26 May 2004
  • Firstpage
    29
  • Lastpage
    32
  • Abstract
    NPL has recently validated a new spherical near-field range. This range is built inside a 15 m by 15 m by 7.5 m anechoic chamber which also houses an extrapolation range and a probe calibration range. The spherical near-field range has been designed to work over an approximate frequency range of 0.5 GHz to 40 GHz, with a quiet zone up to 3 m diameter. This paper describes this new range and the results of the initial validation measurements. It compares the measurement of a standard gain horn moved to two positions in the quiet zone.
  • Keywords
    UHF measurement; anechoic chambers (electromagnetic); antenna testing; calibration; microwave measurement; millimetre wave measurement; 15 m; 7.5 m; NPL; anechoic chamber; antenna calibration; antenna measurements; extrapolation range; microwave antennas; probe calibration range; spherical near-field range; standard gain horn;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Antenna Measurements and SAR, 2004. AMS 2004. IEE
  • ISSN
    0537-9989
  • Print_ISBN
    0-86341-415-X
  • Type

    conf

  • DOI
    10.1049/ic:20040071
  • Filename
    1514887