DocumentCode
2124704
Title
Research on energy of an office building equipped high permeability with Low-E window in Xinxiang
Author
Yang, Cuina ; Yuan, Dawei ; Jia, Yanhui
Author_Institution
Dept. of Building Eng., Xinxiang Univ., Xinxiang, China
fYear
2012
fDate
21-23 April 2012
Firstpage
508
Lastpage
511
Abstract
Energy-saving of high permeability with Low-E window in Xinxiang was studied. The software of DeST was used to simulate the air-conditioning system and heating system load under the office building of Xinxiang equipped ordinary glass and high permeability with Low-E window. The results showed that high permeability with Low-E window was fitted in Xinxiang. Annual cooling, heat load and annual cooling consumption, heat loss by high permeability with Low-E window compared with ordinary glass, down 10%, 26%, 3%, 41%. Great potential for energy saving.
Keywords
air conditioning; building management systems; energy conservation; glass; heating; mechanical engineering computing; windows (construction); DeST software; Xinxiang; air-conditioning system; annual cooling consumption; energy-saving; heat loss; heating system load; high-permeability-with-low-E window; office building energy; Atmospheric modeling; Floors; Heating; Permeability; Temperature distribution; Windows; DeST; energy-saving; high permeability with Low-E window; simulate;
fLanguage
English
Publisher
ieee
Conference_Titel
Consumer Electronics, Communications and Networks (CECNet), 2012 2nd International Conference on
Conference_Location
Yichang
Print_ISBN
978-1-4577-1414-6
Type
conf
DOI
10.1109/CECNet.2012.6201910
Filename
6201910
Link To Document