Title :
A simple analytical estimate of the loss parameter of a large tapered chamber
Author_Institution :
Lab. of Nucl. Studies, Cornell Univ., Ithaca, NY, USA
Abstract :
In the case of a cylindrical chamber that is very large compared with the bunch length, and tapers on each end, an estimate for the loss parameter may be made by first making some assumptions about the distribution of electromagnetic fields, and then calculating the electromagnetic energy left behind when the bunch leaves the chamber. The result is an analytic formula for the loss parameter, with no free or empirical parameters, that agrees well with TBCI calculations of a 20 degrees tapered chamber. This formula has intuitive appeal and is especially useful in providing design assistance as to the best taper angle, diameter, and chamber lengths.<>
Keywords :
electromagnetic fields; losses; chamber lengths; cylindrical chamber; diameter; electromagnetic fields; large tapered chamber; loss parameter; taper angle; Beams; Conductivity; Electromagnetic fields; Electromagnetic measurements; Electromagnetic reflection; Energy measurement; Geometry; Loss measurement; Optical reflection; Shape;
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
DOI :
10.1109/PAC.1991.164443