DocumentCode :
2125817
Title :
Methods for intracardiac electrogram compression suitable with implantable devices
Author :
Rossi, P. ; Casaleggio, A. ; Chiappalone, M. ; Morando, M. ; Corbucci, G. ; Reggiani, M. ; Sartori, G. ; Chierchia, S.
Author_Institution :
Cardiology Div., San Martino Hosp., Genova, Italy
fYear :
2001
fDate :
2001
Firstpage :
257
Lastpage :
260
Abstract :
Studies methods for intracardiac electrogram compression that are suitable for implementation in implantable devices. The algorithms are based on piecewise linear approximation (PLA) methods and beat detection (the peak method). Intracardiac electrograms were obtained, from the right atrium and ventricle, during electrophysiological studies. The total atrial set consists of 5060 s of bipolar recordings and 680 s of unipolar electrograms; the ventricular data set contains 1210 s of bipolar and 480 s of unipolar signals. The peak method clearly performs better than the others to compress bipolar signals, while PLA methods are needed in order to have reliably compressed unipolar data. Performances over the whole bipolar database (including atrial and ventricular sets) reached an average compression ratio (CR) of 7.6, while first-order piecewise linear approximation on unipolar electrograms reached CR=6.6. These preliminary results show that time consumption can be reduced suitably with real-time compression for implantable devices. The ability to compress and store intracardiac electrograms in implantable devices allows detailed verification of appropriate intervention of the device and it might open up new perspectives in the study of the mechanisms involved in the onset of malignant tachyarrhythmias
Keywords :
bioelectric phenomena; electrocardiography; medical signal processing; pacemakers; piecewise linear techniques; real-time systems; source coding; 1210 sec; 480 sec; 5060 sec; 680 sec; beat detection; bipolar recordings; compression ratio; electrophysiological studies; implantable devices; intervention verification; intracardiac electrogram compression; malignant tachyarrhythmia onset; peak method; performance; piecewise linear approximation; real-time compression; right atrium; right ventricle; unipolar signals; Biomedical electrodes; Cancer; Cardiology; Central Processing Unit; Clocks; Electrophysiology; Frequency; Heart; Piecewise linear approximation; Programmable logic arrays;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computers in Cardiology 2001
Conference_Location :
Rotterdam
ISSN :
0276-6547
Print_ISBN :
0-7803-7266-2
Type :
conf
DOI :
10.1109/CIC.2001.977641
Filename :
977641