• DocumentCode
    2126612
  • Title

    Some new results in calibration of three-phase power/energy comparator in NIM

  • Author

    Lu Zuliang ; Li Min ; Guo Fengying ; Li Xiaotie ; Wang Lei

  • Author_Institution
    Nat. Inst. of Metrol., Beijing, China
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    40
  • Abstract
    For calibration for three-phase power/energy comparator with class degree of 0.01, a standard equipment with the uncertainty better than 0.01% will be essential. In this paper the relevant work in NIM is reported, including composition of the equipment, influence among phases and comprehension of uncertainty.
  • Keywords
    Calibration; Comparators (circuits); Measurement uncertainty; Power measurement; 0.5 to 100 A; 0.5A to 100A; 50 to 400 V; 50V to 400V; NIM; calibration; domestic meters; standard equipment; three-phase power/energy comparator; uncertainty; Calibration; Current measurement; Energy measurement; Instruments; Matrix converters; Metrology; Power measurement; Power supplies; Pulse measurements; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.850865
  • Filename
    850865