For calibration for three-phase power/energy comparator with class degree of 0.01, a standard equipment with the uncertainty better than 0.01% will be essential. In this paper the relevant work in NIM is reported, including composition of the equipment, influence among phases and comprehension of uncertainty.
Keywords
Calibration; Comparators (circuits); Measurement uncertainty; Power measurement; 0.5 to 100 A; 0.5A to 100A; 50 to 400 V; 50V to 400V; NIM; calibration; domestic meters; standard equipment; three-phase power/energy comparator; uncertainty; Calibration; Current measurement; Energy measurement; Instruments; Matrix converters; Metrology; Power measurement; Power supplies; Pulse measurements; Uncertainty;