Title :
International comparison of power measurements at 62 GHz
Author_Institution :
BNM-LCIE, Fontenay-aux-Roses, France
Abstract :
A BIPM international key-comparison of power measurements at 62 GHz (GT-RF/95-1) has been carried out between four national metrology institutes. The BNM-LCIE acted as pilot laboratory. The results show very good agreement in measuring the effective efficiency and the magnitude of reflection coefficient for the unique IEC R620 waveguide thermistor mount involved in the comparison.
Keywords :
Calorimeters; IEC standards; Microwave reflectometry; Millimeter wave measurement; Power measurement; Transfer standards; 62 GHz; IEC R620 waveguide thermistor mount; effective efficiency; international comparison; linear regression; national standards; power measurements; reflection coefficient; travelling standard; waveguide adapter; waveguide microcalorimeter; waveguide standard; Frequency; IEC standards; Laboratories; Measurement standards; Metrology; NIST; Particle measurements; Power measurement; Reflection; Thermistors;
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2000 Conference on
Conference_Location :
Sydney, NSW, Australia
Print_ISBN :
0-7803-5744-2
DOI :
10.1109/CPEM.2000.850874