Abstract :
Measurements on a pulse generator, which was made and characterised by NML, Australia, have been made at NRC in Canada and PTB in Germany. The calculated and measured peak values agree to /spl plusmn/0.5% and the front times to /spl plusmn/2.5%.
Keywords :
Calibration; Field effect transistor switches; High-voltage techniques; Measurement standards; Pulse generators; Pulse measurement; Voltage measurement; MOSFET switches; high voltage impulse calibration; international comparison; matched calibrator; peak values; pulse calibrator; pulse generator; simulation; Calibration; Circuit simulation; Electric variables measurement; Laboratories; MOSFETs; Measurement standards; Power measurement; Pulse measurements; Switches; Voltage;