DocumentCode
2127345
Title
Survey and alignment of an MLI model 1.2-400 synchrotron light source
Author
Pearce, W.J.
Author_Institution
Maxwell Lab. Inc., Richmond, CA, USA
fYear
1991
fDate
6-9 May 1991
Firstpage
822
Abstract
A cost effective technique was developed for the timely alignment of the magnets, support stands, and diagnostic equipment using readily available instrumentation. The procedure includes use of a commercially available theodolite coordinate measurement system for alignment of the dipole magnets, and optical tooling techniques for smoothing out errors in the position of the quadrupoles to submillimeter tolerances. The monument network, fiducialization of magnets and supports, and special tooling are discussed.<>
Keywords
particle sources; position measurement; MLI model 1.2-400 synchrotron light source; diagnostic equipment; dipole magnets; magnet alignment; optical tooling techniques; support stands; theodolite coordinate measurement system; Coordinate measuring machines; Costs; Instruments; Lamination; Light sources; Linear particle accelerator; Magnets; Steel; Synchrotrons; Theodolites;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location
San Francisco, CA, USA
Print_ISBN
0-7803-0135-8
Type
conf
DOI
10.1109/PAC.1991.164453
Filename
164453