• DocumentCode
    2128585
  • Title

    Maintenance and development of the capacitance unit at CENAM

  • Author

    Moreno, J.A. ; Hanke, R.

  • Author_Institution
    Centro Nacional de Metrol., Qro, Mexico
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    218
  • Lastpage
    219
  • Abstract
    Aiming to relating the Farad to the Ohm, reproduced at Centro Nacional de Metrologia (CENAM) by means of the Quantized Hall Effect (QHE), a development project was planed. The results of the construction of a capacitance bridge that constitutes the first step to achieve this objective are presented.
  • Keywords
    bridge instruments; calibration; capacitance measurement; measurement standards; quantum Hall effect; units (measurement); CENAM; Centro Nacional de Metrologia; Farad; Ohm; Quantized Hall Effect; capacitance bridge; capacitance unit; Bridge circuits; Calibration; Capacitance; Capacitors; Coaxial components; Equivalent circuits; Hall effect; Resistors; Silicon compounds; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.850954
  • Filename
    850954