    Evaluation of AC-DC transfer standards in the mV-range

  • Author

    Rudler, K.-E. ; Tarasso, V.

  • Author_Institution
    SP Swedish Nat. Testing & Res. Inst., Boras, Sweden
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    230
  • Lastpage
    231
  • Abstract
    Four different methods used to establish traceability of AC-voltage in the mV-range are discussed. From a reference level based on multijunction thermal converters, voltage step-down is made using thermal voltage converters, micropotentiometers and resistive voltage dividers. A method based on summing of AC-voltages is also used. The results of the different methods are compared and found to be in good agreement.
  • Keywords
    calibration; converters; potentiometers; transfer standards; voltage dividers; voltage measurement; AC voltage traceability; AC voltages summing; AC-DC transfer standards; micropotentiometers; multijunction thermal converters; phase controlled voltage buildup; resistive voltage dividers; thermal voltage converters; voltage step-down; Frequency; Heat transfer; Measurement standards; Noise measurement; Resistance heating; Resistors; Speech synthesis; Testing; Thermal resistance; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.850960