• DocumentCode
    2130959
  • Title

    100 kV DC voltage standard divider of the shielded type

  • Author

    Marx, R.

  • Author_Institution
    Phys. Tech. Bundesanstalt, Braunschweig, Germany
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    417
  • Lastpage
    418
  • Abstract
    A shielded high-voltage divider equipped with a temperature control system has been developed for the highly precise measurement of high DC voltages of up to 100 kV. The measuring divider consists of 101 highly precise wire-wound resistors with a total resistance of about 1 G/spl Omega/ and has been set up in a compressed gas vessel under sulphur hexafluoride (SF/sub 6/). The measuring divider is accommodated in an electrode arrangement under potential control, in a homogeneous electrical field, temperature control being ensured by Peltier elements. The nominal scaling factors are 100:1 and 10000:1. The experimental investigation of all resistors and influence quantities as well as the shielded construction and the temperature control system have allowed an uncertainty of 2*10/sup -6/ (k=2) to be achieved.
  • Keywords
    measurement standards; measurement uncertainty; resistors; shielding; voltage dividers; voltage measurement; 0 to 100 kV; DC voltage measurement; Peltier elements; SF/sub 6/; compressed gas vessel; electrode arrangement; homogeneous electrical field; nominal scaling factors; shielded high-voltage divider; temperature control system; voltage standard; wire-wound resistors; Electrical resistance measurement; Electrodes; Pressure measurement; Resistors; Sulfur hexafluoride; Temperature control; Temperature dependence; Temperature distribution; Time measurement; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.851053
  • Filename
    851053