• DocumentCode
    2131754
  • Title

    Active filter for the DESY III dipole circuit

  • Author

    Bothe, W.

  • Author_Institution
    DESY, Hamburg, Germany
  • fYear
    1991
  • fDate
    6-9 May 1991
  • Firstpage
    932
  • Abstract
    The DESY (Deutsches Elektronen-Synchrotron) III dipole circuit is now operated in a ramp mode cycle with a 3.6-s repetition rate. Excitation is done by a 12-pulse thyristor converter, followed by a passive filter. The existing current control could be improved by addition of an active filter. The use of a more efficient passive filter reduces the size of the active filter and does not deteriorate the dynamic behavior. The design of the control loops and the results of the simulation are presented.<>
  • Keywords
    active filters; nuclear electronics; particle accelerator accessories; power supplies to apparatus; proton accelerators; synchrotrons; DESY III dipole circuit; active filter; control loops; current control; passive filter; ramp mode cycle; thyristor converter; Active filters; Automatic control; Feedback circuits; Low pass filters; Magnets; Passive filters; Power harmonic filters; Regulators; Synchrotrons; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
  • Conference_Location
    San Francisco, CA, USA
  • Print_ISBN
    0-7803-0135-8
  • Type

    conf

  • DOI
    10.1109/PAC.1991.164494
  • Filename
    164494