Title :
A new method for measuring ratios of dc voltages from 10 V to 1100 V
Author_Institution :
Meas. Stand. Lab. of New Zealand, Lower Hutt, New Zealand
Abstract :
A new reference-step method is described for measuring the ratio of two dc voltages in the range, 10 V to 1100 V, not covered by the Josephson voltage standard. The method requires a voltmeter and switchable voltage source and can achieve uncertainties of a few parts in 10/sup 7/ of the ratio.
Keywords :
measurement standards; measurement uncertainty; voltage measurement; voltmeters; 10 V to 1100 V; 10 to 1100 V; Datron; Fluke; dc voltage measurement; measurement uncertainties; reference-step method; switchable voltage source; voltmeter; Analog-digital conversion; Calibration; Circuits; Impedance; Laboratories; Measurement standards; Resistors; Time measurement; Voltage; Voltmeters;
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2000 Conference on
Conference_Location :
Sydney, NSW, Australia
Print_ISBN :
0-7803-5744-2
DOI :
10.1109/CPEM.2000.851187