  • Title

    Evaluation of the performance of C.S.I.O. pulse oximeter

  • Author

    Randhawa, S.S. ; Ahluwalia, S.S. ; Gupta, R.C.

  • Author_Institution
    Central Sci. Instrum. Organ., Chandigarh, India
  • fYear
    1995
  • fDate
    15-18 Feb 1995
  • Firstpage
    13516
  • Lastpage
    13881
  • Abstract
    The oxygen present in blood is almost entirely loosely combined with haemoglobin. Oxygen capacity and oxygen content have long been measured by the Van Slyke volumetric and manometric apparatus. A number of workers have used spectrophotometric readings of blood at different wavelengths to estimate oxygen saturation. Instruments using reflection oximetry which use the difference in reflection of light by oxyhaemoglobin and haemoglobin are also used. CSIO has developed a Pulse Oximeter in which oxygen saturation is calculated by measuring the difference between the absorption spectra of oxygenated haemoglobin and deoxygenated haemoglobin with noninvasive means. The instrument is calibrated with Ohmeda and Nellcor instrument. Blood oxygen saturation (SaO2) of student trainees in the age group of 20-25 years and CSIO employees in the age group of 40-45 years were compared with the assay of the same person using the Nellcor Instrument. A good correlation was found between the results from the two instruments. The mean deviation and standard deviation between two instruments were found to be within acceptable limits. The results obtained at PGI Chandigarh during clinical trials on neonates are also discussed
  • Keywords
    biomedical equipment; biomedical measurement; blood; chemical variables measurement; infrared spectra; oxygen; visible spectra; 20 to 25 y; 40 to 45 yr; CSIO employees; CSIO pulse oximeter performance evaluation; O2; Ohmeda & Nellcor instrument; PGI Chandigarh; Van Slyke volumetric/manometric apparatus; clinical trials; light reflection; medical instrumentation; neonates; oxygen capacity; oxygen content; oxyhaemoglobin; reflection oximetry; student trainees; Absorption; Blood; Clinical trials; Instruments; Optical reflection; Oxygen; Pediatrics; Pulse measurements; Volume measurement; Wavelength measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1995 and 14th Conference of the Biomedical Engineering Society of India. An International Meeting, Proceedings of the First Regional Conference., IEEE
  • Conference_Location
    New Delhi
  • Print_ISBN
    0-7803-2711-X
  • Type

    conf

  • DOI
    10.1109/RCEMBS.1995.508678
  • Filename
    508678