• DocumentCode
    2142116
  • Title

    A resistive BPM for Mini-LIA

  • Author

    Le Xu ; Shu-Xin Zheng

  • Author_Institution
    Dept. of Eng. Phys., Tsinghua Univ., Beijing, China
  • fYear
    2008
  • fDate
    6-11 July 2008
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    A prototype of resistive BPM (Beam Position Monitor) was designed and built for Mini-LIA. The design parameters and bench test results are presented. A beam displacement nearly 1mm off-axis can be observed. The relationship between the signal amplitude and decay time constant to current rising time was studied. In conclusion, some factors and phenomenon in the experiment are analyzed.
  • Keywords
    particle beam diagnostics; MiniLIA; beam displacement; bench test results; current rising time; decay time constant; design parameters; resistive beam position monitor; signal amplitude; Electric variables measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    High Power Particle Beams (BEAMS), 2008 17th International Conference on
  • Conference_Location
    Xian
  • Type

    conf

  • Filename
    6202915