Title : 
Vacuum breakdown in the triode with oxide-nickel cathode
         
        
            Author : 
Zilberman, M.M. ; Kogel, M.L.
         
        
            Author_Institution : 
Sci.-Ind. Firm "Phon", Ryazan, Russia
         
        
        
        
        
            Abstract : 
Vacuum breakdown in the triode with oxide-nickel cathode was investigated. It was determined that if the ratio of the negative grid potential to cut-off potential was more than 1.75, then discharge from anode-grid gap did not penetrate in the grid-cathode gap.
         
        
            Keywords : 
cathodes; triodes; vacuum breakdown; anode-grid gap discharge; grid-cathode gap; negative grid otential to cut-off potential ratio; oxide-nickel cathode; triode; vacuum breakdown; Anodes; Capacitors; Cathodes; Circuit testing; Electric breakdown; Nickel; Pulse modulation; Switches; Vacuum breakdown; Voltage;
         
        
        
        
            Conference_Titel : 
Discharges and Electrical Insulation in Vacuum, 2002. 20th International Symposium on
         
        
            Print_ISBN : 
0-7803-7394-4
         
        
        
            DOI : 
10.1109/ISDEIV.2002.1027446