DocumentCode :
2150508
Title :
Correction of skew-quadrupole errors in RHIC
Author :
Dell, G.F. ; Hahn, H. ; Lee, S.Y. ; Parzen, G. ; Tepikian, S.
Author_Institution :
Brookhaven Nat. Lab., Upton, NY, USA
fYear :
1991
fDate :
6-9 May 1991
Firstpage :
1627
Abstract :
The correction scheme for skew-quadrupole (a/sub 1/) errors in the Relativistic Heavy Ion Collider is presented. The a/sub 1/ errors result from fabrication and from installation errors. At the selected betatron tune of nu /sub x/=28.826 and nu /sub y/-28.820, the principal resonances driven by a/sub 1/ errors are nu /sub x/- nu /sub y/=0, the sum resonances near nu /sub x/+ nu /sub y/ which cause residual tune splitting and distortion of beta function, and nu /sub y/=28 and 29 which cause vertical dispersion. Skew quadrupole correctors located in the insertions and arcs will be used to correct the coupling and sum resonances and, if required, separate correctors in the arcs could be used for vertical dispersion correction.<>
Keywords :
beam handling equipment; beam handling techniques; ion accelerators; synchrotrons; RHIC; Relativistic Heavy Ion Collider; a/sub 1/ errors result; arcs; beta function; installation errors; principal resonances; residual tune splitting; selected betatron tune; skew-quadrupole errors; sum resonances; vertical dispersion; Coils; Dispersion; Error correction; Fabrication; Laboratories; Measurement errors; Power supplies; Resonance; Sorting; Structural beams;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
Type :
conf
DOI :
10.1109/PAC.1991.164725
Filename :
164725
Link To Document :
بازگشت