Title :
Measurement of longitudinal impedance for a kaon test pipe model with TSD-calibration method
Author :
Yin, Y. ; Oram, C. ; Ilinsky, N. ; Reinhardt-Nikulin, P.
Author_Institution :
TRIUMF, Vancouver, BC, Canada
Abstract :
Measurements of longitudinal impedances for a kaon factory beam pipe model by means of the TSD-calibration method are reported. The experimental method and the results are discussed. The frequency band is from 48 MHz up to 900 MHz, within which range the method produces measured impedances accurate enough to be useful in indicating whether a test pipe will have a suitably low impedance.<>
Keywords :
beam handling equipment; particle beam diagnostics; 48 to 900 MHz; TSD-calibration method; kaon factory beam pipe; kaon test pipe model; longitudinal impedances; Calibration; Coaxial cables; Cutoff frequency; Impedance measurement; Mesons; Optical reflection; Phase measurement; Production facilities; Strips; Testing;
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
DOI :
10.1109/PAC.1991.164757