  • Abstract
    An instability disruptive to high current main ring operation is the vertical resistive wall instability. Tunes, chromaticities, and feedback loop gains must be continuously adjusted to preserve the beam intensity at injection. Results of frequency and time domain measurements aimed at understanding the sensitivity of the beam to this instability are presented. The influence of selected accelerator parameters is studied in detail. In addition, the effectiveness of various cures is reviewed.<>
  • Keywords
    particle beam diagnostics; proton accelerators; synchrotrons; Fermilab Main Ring; accelerator parameters; chromaticities; feedback loop gains; high current main ring operation; instability; time domain measurements; vertical resistive wall instability; Acceleration; Bandwidth; Damping; Feedback loop; Frequency measurement; Laboratories; Performance evaluation; Radio frequency; Shock absorbers; Spectral analysis;