DocumentCode :
2156036
Title :
Double parity sparing for improvement of performance and reliability in disk arrays
Author :
Lee, Min-Young ; Park, Myong-Soon
Author_Institution :
Dept. of Comput. Sci., Korea Univ., Seoul, South Korea
fYear :
1996
fDate :
12-14 Jun 1996
Firstpage :
345
Lastpage :
348
Abstract :
RAID level 5 disk arrays provide reliable, cost-effective secondary storage with high performance. Sparing schemes have been proposed to improve the reliability and the performance of RAID 5 disk arrays. In this paper, we propose a new sparing technique, double parity sparing. We evaluate the performance and reliability of the proposed scheme in various modes of operation. We present results from simulations to show that the proposed scheme offers better performance in some modes. Also, it is shown that the proposed scheme provides better reliability
Keywords :
fault tolerant computing; magnetic disc storage; memory architecture; performance evaluation; redundancy; RAID 5 disk arrays; disk arrays; double parity sparing; performance; reliability; simulations; Computer science; Maintenance; Merging; Phased arrays;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Parallel Architectures, Algorithms, and Networks, 1996. Proceedings., Second International Symposium on
Conference_Location :
Beijing
ISSN :
1087-4089
Print_ISBN :
0-8186-7460-1
Type :
conf
DOI :
10.1109/ISPAN.1996.509006
Filename :
509006
Link To Document :
بازگشت