Title :
The influence of discharge voltage on ESD parameters for air discharge
Author :
Yuan Qingyun ; Liu Shanghe ; Zhang Xijun ; Xiao Zhiwei
Author_Institution :
Electrostatic & Electromagn. Protection Inst., Mech. Eng. Coll., Shijiazhuang, China
Abstract :
In this paper, a new ESD testing system was designed and the influence of discharge voltage on ESD parameters, e.g. peak value of discharge current, rise time and peak to peak value of induced voltage in a semi-circular loop antenna, and also the reproducibility of experimental results were analyzed used the system. It was concluded that as the approaching speed was constant, the variations of ESD parameters with discharge voltage were divided into three regions: ´Townsend region´ ´Transition region´ and ´Streamer region´ the field strength generated at low discharge voltage was stronger than that at high discharge voltage, better reproducibility could be also obtained at low discharge voltage.
Keywords :
electrostatic discharge; loop antennas; ESD testing system; air discharge; discharge current; discharge voltage; electrostatic discharge; rise time; semi-circular loop antenna; streamer region; townsend region; transition region; Antenna accessories; Breakdown voltage; Current measurement; Electrostatic discharge; Humidity; Low voltage; Oscillators; Reproducibility of results; Surface discharges; System testing; ESD parameters; air discharge; discharge voltage;
Conference_Titel :
Environmental Electromagnetics, 2009. CEEM 2009. 5th Asia-Pacific Conference on
Conference_Location :
Xian
Print_ISBN :
978-1-4244-4344-4
DOI :
10.1109/CEEM.2009.5304221