• DocumentCode
    2159991
  • Title

    ACPR to third order interception point and 1 dB compression point new relationship

  • Author

    Lecheminoux, Laurent ; Villegas, Martine

  • Author_Institution
    Pole d´´Electronique Hautes Fréquences du Polytechicum de Marne-la-Vallée, Laboratoire signaux et télécommunications - Groupe ESIEE - Cité Descartes - 93162 Noisy-le-Grand Cedex, FRANCE. lechemil@esiee.fr
  • fYear
    2000
  • fDate
    Oct. 2000
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    New relationship between Adjacent Channel Power Ratio (ACPR) to the 1dB compression point (PLI), third order intercept point (IP3) and the difference in dB between those values is presented. To get this, it´s necessary to find a formula to estimate the non-linearity of the amplifier using a fifth order Taylor series. The coefficients´ Taylor series are related to the linear gain and to the difference between the third-order intercept point and the 1dB compression point.
  • Keywords
    Digital communication; Frequency; Gain; Nonlinear equations; Power amplifiers; Radiofrequency amplifiers; Signal to noise ratio; Taylor series; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 2000. 30th European
  • Conference_Location
    Paris, France
  • Type

    conf

  • DOI
    10.1109/EUMA.2000.338635
  • Filename
    4139961