DocumentCode :
2162321
Title :
Dynamic aperture effects due to linear coupling
Author :
Parzen, G.
Author_Institution :
Brookhaven Nat. Lab., Upton, NY, USA
fYear :
1991
fDate :
6-9 May 1991
Firstpage :
1875
Abstract :
The studies described show that the stability limit, A/sub SL/, depends on the starting location around the ring. This variation in A/sub SL/ around the ring can be correlated with the variation in the betatron distortion for particles starting at different places around the ring. It is proposed that the average of the A/sub SL/ found by starting at each of the QF, the focusing quadrupoles in the arcs, can be taken as a measure of the dynamic aperture. It is found that the average A/sub SL/ is reduced by about 15% by the random skew quadrupole field error multipoles expected in the RHIC (Relativistic Heavy Ion Collider).<>
Keywords :
ion accelerators; particle beam diagnostics; synchrotrons; RHIC; Relativistic Heavy Ion Collider; betatron distortion; dynamic aperture; focusing quadrupoles; particle beam diagnostics; random skew quadrupole field error multipoles; stability limit; Apertures; Distortion measurement; Laboratories; Lattices; Magnetic field measurement; Magnets; Nonlinear distortion; Stability;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
Type :
conf
DOI :
10.1109/PAC.1991.164807
Filename :
164807
Link To Document :
بازگشت