Title :
Installation of the Legnaro ECR ion source
Author :
Cavenago, M. ; Bisoffi, G. ; Carugno, G. ; Cervellera, F. ; Fortuna, G. ; Moisio, M.F. ; Palmieri, V. ; Rudolph, K.
Author_Institution :
Lab. Nazionali di Legnaro, INFN, Italy
Abstract :
The mechanical parts of the 1 4.4-GHz Legnaro ECR (electron cyclotron resonance) ion source ´Alice´, including the 24 bar NdFeB Halbach hexapole, were built. A newly designed extractor was implemented, with a tapered focus electrode and a reentrant puller. The source is expected to inject a superconductive linac, which is being completed, via an RFQ (radio frequency quadrupole).<>
Keywords :
ion sources; linear accelerators; 24 bar NdFeB Halbach hexapole; Alice; Legnaro ECR ion source; RFQ; electron cyclotron resonance; extractor; radio frequency quadrupole; reentrant puller; superconductive linac; tapered focus electrode; Bars; Coils; Cyclotrons; Electrons; Ion sources; Laboratories; Linear particle accelerator; Plasma confinement; Plasma sources; Testing;
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
DOI :
10.1109/PAC.1991.164827