DocumentCode
2165204
Title
Comparison of the measurement method for surface transfer impedance in frequency-domain and time-domain
Author
Zhou Ying-Hui ; Shi Li-Hua ; Bi-hua, Zhou ; Cheng, Gao ; Bin, Chen
Author_Institution
Nanjing Eng. Inst., Nanjing, China
fYear
2009
fDate
16-20 Sept. 2009
Firstpage
54
Lastpage
57
Abstract
Aimed to acquire the screening efficiency of the shielded coaxial cable a time-domain measurement method is proposed and a test system based on the triaxial test fixture is designed. By using FFT, time-domain test result can be transformed in to frequency-domain. Comparison shows they fit well with each other. The proposed time-domain test method provides a more straight way to observe the screen efficiency of cables under pulsed fields.
Keywords
cable shielding; coaxial cables; fast Fourier transforms; time-domain analysis; frequency-domain measurement; screening efficiency; shielded coaxial cable; surface transfer impedance; time-domain measurement; Cables; Circuit testing; Frequency domain analysis; Frequency measurement; Impedance measurement; Probes; Surface impedance; System testing; Time domain analysis; Voltage; time-domain measurement; transfer impedance; triaxial method;
fLanguage
English
Publisher
ieee
Conference_Titel
Environmental Electromagnetics, 2009. CEEM 2009. 5th Asia-Pacific Conference on
Conference_Location
Xian
Print_ISBN
978-1-4244-4344-4
Type
conf
DOI
10.1109/CEEM.2009.5304458
Filename
5304458
Link To Document