• DocumentCode
    2165716
  • Title

    A new approach to implement a defect tolerant power distribution network in WSI circuits

  • Author

    Yung, Michael W. ; Little, Michael J.

  • Author_Institution
    Hughes Res. Lab., Malibu, CA, USA
  • fYear
    1991
  • fDate
    29-31 Jan 1991
  • Firstpage
    215
  • Lastpage
    222
  • Abstract
    An efficient approach for implementing a defect-tolerant power distribution network suitable for WSI (wafer scale integration) circuits is proposed. The network is not segmented but relies on a thermal imaging technique for defect localization and laser cutting for defect isolation. Power bus designs for this approach are described. Preliminary, experimental results have verified the design concepts
  • Keywords
    VLSI; fault location; infrared imaging; laser beam machining; temperature measurement; WSI circuits; defect isolation; defect localization; defect tolerant power distribution network; design concepts; experimental results; laser cutting; power bus designs; temperature mapping; thermal imaging technique; thermography; wafer scale integration; Circuit testing; Image segmentation; Infrared imaging; Intelligent networks; Joining processes; Liquid crystals; Optical imaging; Power lasers; Power supplies; Power systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Wafer Scale Integration, 1991. Proceedings., [3rd] International Conference on
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-8186-9126-3
  • Type

    conf

  • DOI
    10.1109/ICWSI.1991.151718
  • Filename
    151718