• DocumentCode
    2169379
  • Title

    ARM-based new ship fire alarm-control and data transmission system

  • Author

    Lang, Ping ; Gao, Ming-Yu ; He, Zhi-Wei

  • Author_Institution
    Dept. of Electron. & Inf., Hangzhou Univ. of Electron. Sci. & Technol., Hangzhou, China
  • fYear
    2011
  • fDate
    9-11 Sept. 2011
  • Firstpage
    4192
  • Lastpage
    4195
  • Abstract
    Given the traditional use of sensors of temperature, humidity, smoke to identify the fire hazard, this design adds the image recognition algorithm based on OpenCV to identify fire through capturing images with camera, and caculates the probability of fire hazard according to weight of four factors that influence fire occurrence. The weight is determined by integrated multifactor probability model. Integrated fieldbus Redundancy technology is used in transmission of data on Ethernet and CAN. The practice has showed that the system achieved stability, high reliability, fast, and accuracy. The alarm is given rapidly when fire hazard happens.
  • Keywords
    alarm systems; data communication; field buses; fires; image recognition; local area networks; ships; ARM-based new ship fire alarm-control; CAN; Ethernet; OpenCV; data transmission system; fieldbus redundancy technology; fire hazard; fire occurrence; image recognition algorithm; integrated multifactor probability model; temperature sensor; Cameras; Fires; Humidity; Marine vehicles; Temperature; Temperature sensors; intelligent fire alarm-control system; multi-sensor information fusion; redundancy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronics, Communications and Control (ICECC), 2011 International Conference on
  • Conference_Location
    Ningbo
  • Print_ISBN
    978-1-4577-0320-1
  • Type

    conf

  • DOI
    10.1109/ICECC.2011.6066346
  • Filename
    6066346