DocumentCode
2172753
Title
Chromaticity corrections in the SLC final focus system
Author
Toge, N. ; Brown, K. ; Burke, D. ; Jacobsen, R. ; Krejcik, P. ; Ziemann, V.
Author_Institution
SLAC, Stanford, CA, USA
fYear
1991
fDate
6-9 May 1991
Firstpage
2067
Abstract
The current technique of measuring the IP (interaction point) chromaticities in the SLC final focus system is presented. A semiempirical correction scheme has been successfully implemented to control the IP chromaticities, as characterized by the waist position dependence on the beam energy to better than 0.5 cm/100 MeV. Several outstanding issues needing further improvement are identified, and possible courses of efforts in the near future are discussed.<>
Keywords
beam handling techniques; electron accelerators; linear accelerators; SLC final focus system; chromaticities; interaction point; linear electron accelerators; Bismuth; Colliding beam accelerators; Colliding beam devices; Contracts; Jacobian matrices; Linear accelerators; Linear particle accelerator; Particle beams; Superconducting magnets; Superluminescent diodes;