• DocumentCode
    2176442
  • Title

    Magnetic measurements of the XLS magnets

  • Author

    Solomon, L. ; Galayda, J. ; Sylvester, C.

  • Author_Institution
    Brookhaven Nat. Lab., Upton, NY, USA
  • fYear
    1991
  • fDate
    6-9 May 1991
  • Firstpage
    2116
  • Abstract
    The magnets designed and built for Phase 1 (200 MeV) of the XLS (X-Ray Lithography Source) project have all been measured and characterized. The measurement system designed and utilized for the Phase-1 180 degrees dipole magnets is reviewed here. Hall-probe measurements of the two dipole magnets, with a field of 1.1 T at 1200 A, are discussed and presented. These dipole magnets presented unique constraints on the measuring system due largely to the bending radius of 0.6037 m, and the absence of a reference surface within the magnetic aperture. Phase 2 (700 MeV) of this project includes replacement of the two room-temperature dipole magnets with superconducting dipoles (3.9 T).<>
  • Keywords
    beam handling equipment; electromagnets; electron accelerators; magnetic field measurement; storage rings; synchrotrons; 1.1 T; 1200 A; 200 MeV; Hall-probe measurements; X-Ray Lithography Source; XLS magnets; dipole magnets; electron storage ring; magnetic aperture; magnetic measurements; measurement system; Apertures; Hall effect devices; Laboratories; Magnetic field measurement; Magnetic variables measurement; Phase measurement; Probes; Superconducting magnets; Synchrotrons; Titanium;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
  • Conference_Location
    San Francisco, CA, USA
  • Print_ISBN
    0-7803-0135-8
  • Type

    conf

  • DOI
    10.1109/PAC.1991.164884
  • Filename
    164884