Abstract
This paper describes the core loss differences in electrical machine laminations under rotating field in the case of clockwise (CW) and counterclockwise (CCW) direction excitation. A novel design of a magnetizing test fixture based on an electromagnetic Halbach array is used to perform measurements on two different non oriented silicon steel samples M36G29 and M19G24 at three different frequencies of interest to the industry 1 kHz, 400 Hz, and 60 Hz. Results are presented and discussed.
Keywords
electric machines; laminations; magnetic cores; silicon; steel; counterclockwise directions; electrical machine laminations; electromagnetic Halbach array; frequency 1 kHz; frequency 400 Hz; frequency 60 Hz; magnetizing test fixture; nonoriented silicon steel samples; rotating field; rotational core loss measurements; Coils; Core loss; Loss measurement; Magnetic field measurement; Magnetic sensors; Rotation measurement; Anisotropy; Halbach array; electrical steel; rotational core loss;