DocumentCode
2181480
Title
Analysis and calculation of magnetic shielding effectiveness for comparators
Author
Shiyan Ren ; Hengchun Ding ; Mingming Li
Author_Institution
Dept. of Electr. Eng., Huazhong Univ. of Sci. & Technol., Wuhan, China
fYear
1994
fDate
June 27 1994-July 1 1994
Firstpage
40
Lastpage
41
Abstract
A method of analyzing and calculating magnetic shielding effectiveness of comparators by means of long rectangular shell model with a magnetic core is developed. The calculation formula is derived. The error between testing results and calculation data for the magnetic shielding effectiveness of 25,000-ampere dc comparator is less than 5 percent.<>
Keywords
calibration; comparators (circuits); electric current measurement; magnetic shielding; measurement errors; 25000 A; analysis; dc comparator; error; magnetic core; magnetic shielding effectiveness; rectangular shell model; Influenza; Linearity; Magnetic analysis; Magnetic cores; Magnetic flux; Magnetic shielding; Shape; Testing; Toroidal magnetic fields;