• DocumentCode
    2183795
  • Title

    Monitoring the 1 /spl Omega/ standard resistor by quantum Hall effect

  • Author

    Kinoshita, J. ; Nakanishi, M. ; Yoshihiro, K. ; Endo, T.

  • Author_Institution
    Electrotech. Lab., Ibaraki, Japan
  • fYear
    1994
  • fDate
    June 27 1994-July 1 1994
  • Firstpage
    192
  • Lastpage
    193
  • Abstract
    Resistance standards at ETL are maintained by quantum Hall effect. Resistance of the 1 /spl Omega/ resistor named 69J101 is monitored. The result is R69J101=1-(5.682/spl plusmn/0.018)/spl times/10/sup -6/+(0.110/spl plusmn/0.003)/spl times/10/sup -6/ t /spl Omega/ where t is time in years from Jan. 1, 1994. The difference of 1 /spl Omega/ standard between ETL and BIPM on 1990 international comparison is reduced from MINUS/0.128 ppm to -0.044 ppm.<>
  • Keywords
    electric resistance measurement; measurement standards; monitoring; quantum Hall effect; resistors; 1 ohm; 1990 international comparison; BIPM; ETL; GaAs; GaAs heterostructure; Si; Si MOSFET; quantum Hall effect; resistance standard; standard resistor; Calibration; Coils; Electrical resistance measurement; Gallium arsenide; Hall effect; Monitoring; Resistors; Time measurement; Uncertainty; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 1994. Digest., 1994 Conference on
  • Conference_Location
    Boulder, CO, USA
  • Print_ISBN
    0-7803-1984-2
  • Type

    conf

  • DOI
    10.1109/CPEM.1994.333265
  • Filename
    333265