DocumentCode
2185142
Title
Quench performance of superconducting quadrupole magnets for the new Fermilab low beta insertion
Author
Gourlay, S.A. ; Carson, J.A. ; Hanft, R. ; Jaffery, T.S. ; Koepke, K. ; Lamm, M.J. ; Mantsch, P.M. ; McInturff, D. ; Mokhtarani, A. ; Orris, D. ; Peterson, T.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
fYear
1991
fDate
6-9 May 1991
Firstpage
2227
Abstract
Construction and testing of the components for the new Tevatron D0/B0 low beta insertion are nearly complete. The devices include superconducting cold iron quadrupoles utilizing a two-shell, cos2 theta coil geometry with a 7.6-cm aperture. The maximum design gradient is 1.41 T/cm at an operating current of 4832 A. They have the highest current density with the highest peak field on the winding of any quadrupole yet built. The authors summarize the quench performance and ramp rate sensitivity of the two-shell design and relate the performance characteristics to the relevant aspects of design and fabrication.<>
Keywords
proton accelerators; superconducting magnets; synchrotrons; Tevatron D0/B0 low beta insertion; Tevatron proton synchrotron; coil geometry; current density; design gradient; performance characteristics; quench performance; ramp rate sensitivity; superconducting magnets; two-shell design; Billets; Copper; Cryogenics; Current density; Iron; Laboratories; Superconducting cables; Superconducting coils; Superconducting magnets; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location
San Francisco, CA, USA
Print_ISBN
0-7803-0135-8
Type
conf
DOI
10.1109/PAC.1991.164922
Filename
164922
Link To Document