Title :
BCR intercomparison of ac-dc current transfer standards
Author :
Klonz, M. ; Bergeest, R. ; Caizergues, A. ; Fraisse, D. ; Winther, C.A.D. ; Pogliano, U. ; Cabiati, F. ; Bosco, G.C. ; Zago, G. ; Dessens, J.T. ; de Vreede, J.P.M. ; Rydler, K.-E. ; Nilsson, H.
Author_Institution :
Physikalisch Tech. Bundesanstalt, Braunschweig, Germany
fYear :
1994
fDate :
June 27 1994-July 1 1994
Firstpage :
421
Lastpage :
422
Abstract :
The established ac-dc current transfer standards and measurement set-ups of EC, IEN, LCIE, PTB, SP and VSL were intercompared in the current range from 10 mA to 20 A and in the frequency range from 10 Hz to 100 kHz. An agreement within 10 ppm to 30 ppm was obtained up to 100 mA, degrading to 100 ppm at 1 A (100 kHz) and 70 ppm at 10 A (20 kHz) and 20 A (5 kHz).<>
Keywords :
electric current measurement; measurement standards; 1 A; 10 Hz to 100 kHz; 10 mA to 20 A; 100 mA; 20 A; 20 kHz; 5 kHz; BCR intercomparison; EC; IEN; LCIE; PTB; SP; VSL; ac-dc current transfer standards; Connectors; Current measurement; Dielectric losses; Frequency measurement; Heat transfer; Laboratories; Measurement standards; Resistance heating; Resistors; Standards development;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements, 1994. Digest., 1994 Conference on
Conference_Location :
Boulder, CO, USA
Print_ISBN :
0-7803-1984-2
Type :
conf
DOI :
10.1109/CPEM.1994.333327
Filename :
333327