Title :
Accuracy assesment of material measurements with a quasi-optical free-space test bench
Author :
Saenz, E. ; Rolo, L. ; van´t Klooster, Kees ; Paquay, M. ; Parshin, V.V.
Author_Institution :
Antenna & Submillimetre Wave Sect., Eur. Space Agency (ESA-ESTEC), Noordwijk, Netherlands
Abstract :
In this paper accurate material measurements at sub-millimetre wave frequencies performed with two different systems are compared. Transmission and reflection results of high quality samples measured with a quasi-optical open resonator and a quasi-optical free-space bench are presented. Based on the comparison between the two results, an accuracy assessment of the transmission set-up is performed.
Keywords :
optical resonators; space communication links; submillimetre wave measurement; accurate material measurements; quasioptical free-space bench; quasioptical free-space test bench; quasioptical open resonator; sub-millimetre wave frequencies; Accuracy; Antenna measurements; Calibration; Loss measurement; Materials; Reflection; Resonant frequency; Quasi-Optical free-space bench; Quasi-Optical open resonator; material characterisation;
Conference_Titel :
Antennas and Propagation (EUCAP), 2012 6th European Conference on
Conference_Location :
Prague
Print_ISBN :
978-1-4577-0918-0
Electronic_ISBN :
978-1-4577-0919-7
DOI :
10.1109/EuCAP.2012.6206324