Title : 
Comparisons of 10 V Josephson array voltage standards between the BNM/LCIE and the BIPM
         
        
            Author : 
Lo-Hive, J.P. ; Reymann, D. ; Geneves, G.
         
        
            Author_Institution : 
BNM/LCIE, Fontenay-aux-Roses, France
         
        
        
            fDate : 
June 27 1994-July 1 1994
         
        
        
        
            Abstract : 
An indirect comparison between the 10 V Josephson array voltage standards of the BNM/LCIE and the BIPM has been carried out using Zener-diode based voltage references as transfer standards. The results show an agreement of 5 parts in 10/sup 9/ with an uncertainty (1/spl sigma/) of 3 parts in 10/sup 9/, mainly due to instability of the Zener references. A direct comparison is to be carried out early in 1994 to avoid this limitation.<>
         
        
            Keywords : 
Zener diodes; measurement standards; superconducting junction devices; voltage measurement; 10 V; 1994; BIPM; BNM/LCIE; Josephson array voltage standards; Zener-diode; instability; transfer standards; uncertainty; voltage references; Battery charge measurement; Calibration; Detectors; Dielectric losses; Dielectric measurements; Josephson junctions; Laboratories; Sensor arrays; Uncertainty; Voltage;
         
        
        
        
            Conference_Titel : 
Precision Electromagnetic Measurements, 1994. Digest., 1994 Conference on
         
        
            Conference_Location : 
Boulder, CO, USA
         
        
            Print_ISBN : 
0-7803-1984-2
         
        
        
            DOI : 
10.1109/CPEM.1994.333439