• DocumentCode
    2188199
  • Title

    Comparisons of 10 V Josephson array voltage standards between the BNM/LCIE and the BIPM

  • Author

    Lo-Hive, J.P. ; Reymann, D. ; Geneves, G.

  • Author_Institution
    BNM/LCIE, Fontenay-aux-Roses, France
  • fYear
    1994
  • fDate
    June 27 1994-July 1 1994
  • Firstpage
    91
  • Lastpage
    92
  • Abstract
    An indirect comparison between the 10 V Josephson array voltage standards of the BNM/LCIE and the BIPM has been carried out using Zener-diode based voltage references as transfer standards. The results show an agreement of 5 parts in 10/sup 9/ with an uncertainty (1/spl sigma/) of 3 parts in 10/sup 9/, mainly due to instability of the Zener references. A direct comparison is to be carried out early in 1994 to avoid this limitation.<>
  • Keywords
    Zener diodes; measurement standards; superconducting junction devices; voltage measurement; 10 V; 1994; BIPM; BNM/LCIE; Josephson array voltage standards; Zener-diode; instability; transfer standards; uncertainty; voltage references; Battery charge measurement; Calibration; Detectors; Dielectric losses; Dielectric measurements; Josephson junctions; Laboratories; Sensor arrays; Uncertainty; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 1994. Digest., 1994 Conference on
  • Conference_Location
    Boulder, CO, USA
  • Print_ISBN
    0-7803-1984-2
  • Type

    conf

  • DOI
    10.1109/CPEM.1994.333439
  • Filename
    333439